In the recent attempts to stimulate alternative energy sources for heating and cooling of buildings, emphasise has been put on utilisation of the ambient energy from ground source heat pump systems (GSHPs) and other renewable energy sources. Exploitation of renewable energy sources and particularly ground heat in buildings can significantly contribute towards reducing dependency on fossil fuels. Geothermal heat pumps (GSHPs), or direct expansion (DX) ground source heat pumps, are a highly efficient renewable energy technology, which uses the earth, groundwater or surface water as a heat source when operating in heating mode or as a heat sink when operating in a cooling mode. It is receiving increasing interest because of its potential to reduce primary energy consumption and thus reduce emissions of the greenhouse gases (GHGs). The main concept of this technology is that it utilises the lower temperature of the ground (approximately <32°C), which remains relatively stable throughout the year, to provide space heating, cooling and domestic hot water inside the building area. The main goal of this study is to stimulate the uptake of the GSHPs. Recent attempts to stimulate alternative energy sources for heating and cooling of buildings has emphasised the utilisation of the ambient energy from ground source and other renewable energy sources. The purpose of this study, however, is to examine the means of reduction of energy consumption in buildings, identify GSHPs as an environmental friendly technology able to provide efficient utilisation of energy in the buildings sector, promote using GSHPs applications as an optimum means of heating and cooling, and to present typical applications and recent advances of the DX GSHPs. The study highlighted the potential energy saving that could be achieved through the use of ground energy sources. It also focuses on the optimisation and improvement of the operation conditions of the heat cycle and performance of the DX GSHP. It is concluded that the direct expansion of the GSHP, combined with the ground heat exchanger in foundation piles and the seasonal thermal energy storage from solar thermal collectors, is extendable to more comprehensive applications.

References

.Allan, M. L., & Philappacopoulus, A. J. (1999). Ground water protection issues with geothermal heat pumps.

Geothermal Resources Council Transactions, 23, 101-105.

.Anandarajah, A. (2003). Mechanism controlling permeability changes in clays due to changes in pore fluids. Journal

of Geotechnical and Geoenvironmental Engineering, 129(2), 163-172.

.ASHRAE, (1995). Commercial/Institutional Ground Source Heat Pump Engineering Manual. American Society of

heating, Refrigeration and Air-conditioning Engineers, Inc. Atlanta, GA: USA.[4].Bejan, A. (2000). Shape and Structure, from Engineering to Nature. Cambridge University Press: London. The many

faces of protease-protein inhibitor interaction. EMBO J. 7, 1303-1130. 2000.

.Bergles, A. E. (1988). Some perspectives on enhanced heat transfer - second generation heat transfer technology.

Journal of Heat Transfer, 110, 1082-1096.

.Bowman, W. J. & Maynes, D. (2001). A Review of Micro-Heat Exchangers Flow Physics, Fabrication Methods and

Application. Proc. ASME IMECE, New York, USA, HTD-24280.

.EPRI and NRECA, (1997). Grouting for vertical geothermal heat pump systems: Engineering design and field

procedures manual. Electric Power Research Institute TR-109169, Palo Alto, CA, and National Rural Electric

Cooperative Association, Arlington, VA.

.Fahlen, Per. (1997). Cost-effective heat pumps for Nordic countries, and heat pumps in cold climates. The 3rd

International Conference, Acadia University, Wolfville, Canada. 1997.

.Fridleifsson, I. B. (2003). Status of geothermal energy amongst the world’s energy sources. Geothermics, 30, 1-27.

. Jo, H. Y., Katsumi, T., Benson, C. H., & Edil, T. B. (2001). Hydraulic conductivity and swelling of nonprehydrated

GCLs permeated with single-species salt solutions. Journal of Geotechnical and Geoenvironmental Engineering,

(7), 557-567.

. Kalbus, E., Reinstrof, F., & Schirmer, M. (2006). Measuring methods for groundwater surface water interactions: a

review. Hydrology and Earth System Sciences, Vol. (10), pp. 873-887.

. Knoblich, K., Sanner, B., & Klugescheid, M. (1993). Ground source heat pumps. Giessener Geologische Schriften,

, pp. 192, Giessen.

. Li, J., Zhang, J., Ge, W. & Liu, X. (2004). Multi-scale methodology for complex systems. Chemical Engineering

Science, 59, 1687-1700.

. Luo, L., & Tondeur, D. (2005). Multiscale optimisation of flow distribution by constructal approach. Particuology,

, 329-336.

. Luo, L., Tondeur, D., Le Gall, H., & Corbel, S. (2007). Constructal approach and multi- scale components. Applied

Thermal Engineering, 27, 1708-1714.

. Luo, L., Fan, Y. & Tondeur, D. (2007). Heat exchanger: from micro to multi- scale design optimisation,

International Journal of Energy Research, 31, 1266-1274.

. Mandelbrot, B. (1982). The Fractal Geometry of Nature, 2nd Ed., W. H. Freeman, San Francisco, California.

. McCray, K. B. (1997). Guidelines for the construction of vertical boreholes for closed loop heat pump systems.

Westerville, OH, National Ground Water Association, pp. 43.

. Petrov, R. J., Rowe, R. K., & Quigley, R. M. (1997). Selected factors influencing GCL hydraulic conductivity,

Journal of Geotechnical and Geoenvironmental Engineering, 123(8): 683-695.

. Philappacopoulus, A. J., & Berndt, M. L. (2001). Influence of debonding in ground heat exchangers used with

geothermal heat pumps. Geothermics, 30(5), 527-545.

. Rafferty, K. (2003). Why do we need thermally enhanced fill materials in boreholes? National Ground Water

Association.

. Ramshaw, C. (1995). Process Intensification in the Chemical Industry, Mechanical Engineering Publications Ltd,

London.

. Rybach, L. & Hopkirk, R. (1995). Shallow and Deep Borehole Heat Exchangers - Achievements and Prospects. Pro.

World Geothermal Congress 1995: 2133-2139.

. Rybach, L., & Eugster, W. J. (1997). Borehole Heat Exchangers to Tap Shallow Geothermal Resources: The Swiss

Success Story. In: S. F. Simmons, O. E.

. Shah, R. K. (1991). Compact Heat Exchanger Technology and Applications, in Heat Exchange Engineering,

Volume 2, Compact Heat Exchangers: Techniques of Size Reduction, eds. E. A. Foumeny and P. J. Heggs, pp. 1–

, Ellis Horwood Limited, London.

. Smith, M. D., & Perry R. L. (1999). Borehole grouting: Field studies and therm performance testing. ASHRAE

Transactions, 105(1), 451-457.

. USEPA, (1997). A short primer and environmental guidance for geothermal heat pumps. U.S.A Environmental

Protection Agency EPA 430-K-97-007, pp. 9

Downloads

Published

2015-06-27