BLOOD PRESSURE MONITORING SYSTEM USING NMR METHOD

Authors

  • Bambang Murdaka Eka Jati Jurusan Fisika, Fakultas MIPA, UGM, Jogjakarta, Indonesia
  • Kusminarto Jurusan Fisika, Fakultas MIPA, UGM, Jogjakarta, Indonesia
  • Agung Bambang SU Jurusan Fisika, Fakultas MIPA, UGM, Jogjakarta, Indonesia
  • Guntur Maruto Jurusan Fisika, Fakultas MIPA, UGM, Jogjakarta, Indonesia

DOI:

https://doi.org/10.53555/eijas.v2i3.17

Keywords:

Blood pressure measurement, NMR method

Abstract

A new blood pressure monitoring system on human arm artery using NMR method has been constructed. The system is a non-invasive blood pressure measurement system which is as sphygmomanometer, but more accurate since it uses the blood pressure pulse wave as in the catheter method. The system has been constructed by varying the wire winding number in the RF coils (varied from 100 to 500 turns) and the cross section area of the RC (varied from 50 to 125 cm2). We found that the biggest NMR signal is attained when the RF coil winding number is 500 turns and the RC cross section is 50 cm2. Data from five subjects give NMR signal (E) in mV for different blood pressure (P) measured by sphygmomanometer in mmHg. We found a linear relation between E and P, but with two different slopes. On small P (from 60 up to 90 mmHg) the slope of E versus P is (101±6) mV/mmHg, while on large P (from 100 up to 130 mmHg) the slope is (203 ± 4) mV/mmHg.

References

Foster, M.A., 1984: Magnetic Resonance in Medicine and Biology, Pergamon Press, Oxford

http://hyperphysics.phyastr.gsu.edu/hbase/hph.html, was accesed October 1st 2005

Kusminarto, 2007: Fisika: Penerapannya dalam Bidang Medis, Pidato Pengukuhan Jabatan Guru Besar pada FMIPA UGM, UGM, Yogyakarta

Valk, J., MacLean, C., Algra, P.R., 1985: Basic Principles of Nuclear Magnetic Resonance Imaging, Elsevier, Amsterdam

Brown, B.H., Smallwood, R.H., Barber, D.C., Lawford, P.V., Hose,D.R., 1999: Medical Physics and Biomedical Engineering, IOP Publishing Ltd, London

Silvennoinen, J., 2002: A Study of NMR Relaxation in Blood-Mechanistic Consideration and Implication for Quantitative Functional MRI, Doctoral Dissertation, Dept. of Biomedical NMR and National Bio-NMR, Univ. of Kuopio, Kuopio

Westbrook, C., 2003: MRI at a Glance, Blackwell Science Ltd, Iowa, USA

Jati, B.M.E., Kusminarto, Bambang, A., Irawan, B.; 2010: Design and Construction of NMR Based Flowing Fluid Monitoring System, 5th Proceedings, Kentingan Physics Forum, Physics Department Sebelas Maret University, Solo

Jati, B.M.E., Kusminarto, Bambang, A., Irawan, B.; 2010: Karakterisasi Koil Penerima dan Koil RF pada Pembuatan Sistem Monitor Tekanan Fluida Mengalir Berbasis Metode NMR, Volume 4 Proceeding Book, 7th Basic Science National Seminar, Unibraw, Malang

Jati, B.M.E.; Kusminarto; Utomo, A.B.S; Irawan, B., 2015: The Characterization of NMR signal for blood pressure monitoring system and Its Testing, Journal of the Medical Sciences, Vol 47 Number 1, Faculty of Medicine UGM, Yogyakarta

Lewis, G.; Gona, P.; Larson, M.; Piehn, J.F.; Benyamin, E.J.; Donnell, C.J.; Levy, D.; Vasan, R.S.; Wang, T.J., 2008: Exercise Blood Pressure and the Risk of Incident Cardiovascular Disease (from the Framingham Heart Study), The American Journal of Cardiology, Vol. 101, p. 1614 – 1620, www.sciencedirect.com

Cerda, A.P.; Aswar, R., 2003: Arterial Stiffness and blood pressure self – measurement with loaned equipment, American Journal of Hypertension, Vol. 16, p. 375 – 380, www.sciencedirect.com

Yarows, S.A.; Patel, K.; Brook, R.; 2001: Rapid Oscillometric Blood Pressure Measurement compared to Conventional Oscillometric Measurement, Blood Pressure Monitoring, Vol. 6 No. 3, p. 145 – 147, Lippincott & Wilkin, Michigan

Zrelak, P.; Cisneros, D.; Carter, T.; Atkinson, R.; 2003: Blood Pressure accurancy in the hospital, Journal of Stroke and Cerebrovascular Diseases, Vol. 12, p. 252; www.sciencedirect.com

Greatorex, C.A., 1982: Instrumentation for the Measurement of Blood Pressure and Flow, Physics in Technology, Dept. Of Clinical Physics, London

Friedman, B.H.; Christie, I.C.; Sargent, S.L.; Weaver, B.J., 2004: Selfreported sensitivity to continous non-invasive blood pressure monitoring via the radial artery, Journal of Psychosomatic Research, Vol. 57, p.119 – 121, www.sciencedirect.com

http://www.patentstorm.us, was accesed February 12th 2010

O’Brien, T.; O’ Malley, K.; 1979: ABC of Blood Pressure Measurement, Britis Medical Journal, London

Downloads

Published

2016-09-27